Study in Pictures🌐 English (United States)
Radon Testing & Mitigation Illustrated

Digital book in PDF · read it on your phone or print it

Radon Testing & Mitigation Illustrated

Placement, closed-house conditions, duplicates, blanks and spikes, the lab report, the sub-slab system and the post-mitigation test. One topic per page: first the drawing, then the numbers you need to remember. Checked against EPA guidance and the current ANSI/AARST standards.

  • 64 illustrated pages
  • English
  • 30-day guarantee
US$ 27US$ 63
Get the book · US$ 27

Price shown for: United States. In other countries, the checkout shows the price that applies there.

About this book

What it is

Placement, closed-house conditions, duplicates, blanks and spikes, the lab report, the sub-slab system and the post-mitigation test. One topic per page: first the drawing, then the numbers you need to remember. Checked against EPA guidance and the current ANSI/AARST standards.

Who This Book Is For
  • You're adding radon to your inspections
  • Your measurement or mitigation exam is coming up
  • You already test or mitigate
What it covers
  1. What Radon Is
  2. How Radon Gets In
  3. The Devices
  4. Placement and Closed-House Rules
  5. Quality Control
  6. Results and Decisions
  7. Mitigation Systems
  8. After the System
  9. Review and Exam Prep
Language
English (United States)
Pages
64
Format
Digital book in PDF · read it on your phone or print it
Price
US$ 27 (United States)
Delivery
This is a digital PDF book sent to your email: nothing is printed or shipped.
30-Day Guarantee
30-day guarantee: if a file doesn't open, if the content isn't what the product page describes, if you were charged twice or the email never arrived, write to us and we'll refund you in full.

Look Inside the Book

U-238 → Ra-226 → Rn-222 → progeny: radon is the gas that moves
U-238 → Ra-226 → Rn-222 → progeny: radon is the gas that moves
Radon leaves well water at showers and faucets; the 300 pCi/L figure is a proposal, not a law.
Radon leaves well water at showers and faucets; the 300 pCi/L figure is a proposal, not a law.
Passive (charcoal, alpha track, electret) vs. active (CRM): one drawn table.
Passive (charcoal, alpha track, electret) vs. active (CRM): one drawn table.
Time-sensitive test: lowest level that could be occupied, even if unfinished. Extended: lowest occupied level.
Time-sensitive test: lowest level that could be occupied, even if unfinished. Extended: lowest occupied level.
Duplicates check precision, blanks check contamination, spikes check accuracy.
Duplicates check precision, blanks check contamination, spikes check accuracy.
Result, dates, device and serial, lab and QC notes: one report, four fields, same order every time.
Result, dates, device and serial, lab and QC notes: one report, four fields, same order every time.
SSD, sealing, sump, SMD and ventilation: one row, one drawing each
SSD, sealing, sump, SMD and ventilation: one row, one drawing each
Post-mitigation test: start ≥ 24 h after the fan runs, test within 30 days of installation
Post-mitigation test: start ≥ 24 h after the fan runs, test within 30 days of installation

Take a Look at the 9 Parts and 60 Topics

What Radon Is

pp. 5-10
  1. From Uranium to Radon: The Decay Chain
  2. Half-Life: 3.8 Days and Why It Matters
  3. Radon vs. Radon Progeny
  4. The Health Risk in One Page
  5. Units: pCi/L, Bq/m³ and Working Levels
  6. The Numbers to Know: 4 and 2

How Radon Gets In

pp. 11-16
  1. Pressure Differential: The House Pulls Soil Gas
  2. Stack Effect, Wind and Exhaust Fans
  3. The Entry Points Map
  4. Foundation Types: Basement, Slab-on-Grade, Crawlspace
  5. Why Two Houses Next Door Differ
  6. Radon in Well Water

The Devices

pp. 17-23
  1. Passive vs. Active Devices
  2. Activated Charcoal Canisters
  3. Alpha Track Detectors
  4. Electret Ion Chambers
  5. Continuous Radon Monitors (CRM)
  6. Short-Term vs. Long-Term Tests
  7. Calibration and the Device's Paperwork

Placement and Closed-House Rules

pp. 24-31
  1. Which Level to Test: The Lowest Livable
  2. Rooms to Avoid
  3. Height Above the Floor
  4. Distance From Walls, Windows and Doors
  5. Away From Drafts, Heat and Sunlight
  6. Closed-House Conditions: 12 Hours Before
  7. What Can Run During the Test
  8. Weather, Duration and When Not to Test

Quality Control

pp. 32-38
  1. Why QC Exists: Proving the Number
  2. Duplicates: Two Devices Side by Side
  3. Relative Percent Difference (RPD)
  4. Blanks: Devices That Never Get Exposed
  5. Spikes: Known Exposure at a Chamber
  6. Control Charts and the QA Plan
  7. Chain of Custody and Records

Results and Decisions

pp. 39-45
  1. Reading a Lab Report
  2. Reading a CRM Curve
  3. Signs of Tampering or Interference
  4. Real Estate Testing Options
  5. Follow-Up Testing Logic
  6. Writing the Report for the Client
  7. Licensing and State Rules

Mitigation Systems

pp. 46-55
  1. Mitigation Methods at a Glance
  2. Diagnostics Before You Design
  3. Sub-Slab Depressurization: The Full System
  4. The Suction Point and the Pit
  5. Piping: Size, Slope and Support
  6. The Fan: Where It Can Go
  7. Exhaust Location Rules
  8. The U-Tube Manometer and System Labels
  9. Sealing: Sump Lids, Cracks and Joints
  10. Crawlspaces: Sub-Membrane Depressurization

After the System

pp. 56-59
  1. Post-Mitigation Test: When and How
  2. Backdrafting and Combustion Safety
  3. System Failure Warnings and Maintenance
  4. Radon-Resistant New Construction

Review and Exam Prep

pp. 60-64
  1. The Whole Job in One Diagram
  2. Placement Rules on One Card
  3. QC and Math on One Card
  4. Mitigation Rules on One Card
  5. Exam-Day Strategy for the Measurement and Mitigation Exams

Who This Book Is For

You're adding radon to your inspections

You get the whole job in the order you'll do it, from where the gas comes from to the post-mitigation test. Each rule is a drawing with the measurement on it.

Your measurement or mitigation exam is coming up

You review placement, QC and mitigation one page at a time, then use the one-card summaries and the 150 exam-style questions to check yourself.

You already test or mitigate

You keep the pages you're unsure about close at hand, printed in the truck, so you check a rule before the client or the agent asks.

Plus: 2 Free Books

Radon Exam-Style Questions: 150 Questions with Explained Answers
BONUS 1

Radon Exam-Style Questions: 150 Questions with Explained Answers

Test yourself on placement, devices, QC math and mitigation, and see in one line why each answer is right.

The 15 Most Common Radon Mistakes, Before and After
BONUS 2

The 15 Most Common Radon Mistakes, Before and After

See each frequent mistake drawn next to the correct setup, from a monitor on the floor to an unsealed sump lid.

30-Day Guarantee

30-day guarantee: if a file doesn't open, if the content isn't what the product page describes, if you were charged twice or the email never arrived, write to us and we'll refund you in full. You pay once. No subscriptions.

Frequently Asked Questions

Is it for me if I already inspect homes and haven't taken an exam in years?

Yes. It's written for people who already work in houses: it skips the classroom tone and shows each rule as a drawing, in the same order as the job.

Where does the content come from?

It's checked against U.S. EPA radon guidance and the current editions of the ANSI/AARST standards (MAH, MS-QA, SGM-SF and CCAH), the standards that NRPP and NRSB candidates study for the measurement and mitigation exams. If your state issues its own radon license, check its rules too: the book has a page on state licensing. Standard values are marked so you can verify them in the current edition.

Is it official material?

No. It's independent illustrated study material. It isn't issued or approved by the EPA, AARST, NRPP, NRSB or any state.

I already have my course manual. What does this add, and does it count as certification?

The manual explains each rule in paragraphs. Here each rule is one page: the drawing, then the numbers in a box, plus three one-card summaries and 150 exam-style questions. It doesn't replace the required course or the standards, and it doesn't give you a certificate or continuing-education credits.

Are the practice questions the ones on the exam?

No. The 150 exam-style questions are written for this book. They are not official questions from any exam.

When and how do I get it?

As a PDF by email, sent to the address you enter at checkout. The 2 bonus books come the same way.

Do I have to pay every month?

No. It's a one-time payment.

Can I have it on paper?

Yes. The PDF is made to print, so you can keep the pages you need in the truck.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

US$ 27US$ 63
Get the book · US$ 27

This is a digital PDF book sent to your email: nothing is printed or shipped.

More books on this topic

Home Inspector Exam Illustrated

Study for the NHIE one house system per page: big labeled cutaway drawings, the defects to recognize, how the exam…

From US$ 27 US$ 63

Electrical Inspector Illustrated

Residential electrical inspection explained one topic per page, each with a big, clear drawing: service entrance…

From US$ 27 US$ 63

Lead Inspector Illustrated

Lead inspection and risk assessment, one topic per page and every concept drawn: XRF readings, paint chip, dust wipe…

From US$ 27 US$ 63

Plumbing Inspector Illustrated

Residential plumbing inspection, one topic per page and drawn: the underground, rough-in and final sequence, DWV and…

From US$ 27 US$ 63

Mechanical Inspector Illustrated

Residential mechanical inspection drawn one topic per page: appliance access and clearances, combustion air, vent…

From US$ 27 US$ 63

Elevator Inspector Illustrated

Elevator and escalator inspection explained one topic per page, each with a big, clear drawing: traction, hydraulic and…

From US$ 27 US$ 63